So, this post provides a guide to the most common Worcester boiler issues and how to fix them. Whether you should attempt to do that on your own is a different matter. We always advise users to call in an expert just to make sure the system is running smoothly. If you need a Worcester boiler repair in London, you might want to give us a call as soon as possible! In this scenario, you’ll have to attach the hose to the two valves — the one that connects to the heating system and the one from the mains water. Next, you’d open the mains tap, then the heating system tap, and wait for the pressure to climb to the correct level. You can then turn off the taps and remove the hose. Pressure Gauge Fault The codes above point to a leak in the system, which is the most common cause of any boiler losing pressure. When the Pressure Rises Too Much If this doesn’t work, you may need a new boiler. If you do, find out how much a new boiler costs now a get a fixed price quote online. A leak that’s causing boiler pressure loss needn’t be in the boiler itself. Whilst it can affect many of the boiler’s internal components, a leak may just as well occur anywhere else in the heating system, including radiators, valves, pipework, and towel rails.

Yes. You can repressurise a boiler by yourself, and you should definitely learn how to repressurise a combi boiler if you don’t already know. You may be dealing with a faulty diverter valve if the radiators don’t turn on while the hot water taps are still working. Having only lukewarm water is another indication of an issue with the diverter valve. Bottom Line on Common Worcester Boiler Faults The boiler pressure should rise by about 0.3-0.5 bar when the boiler starts heating water, but should never rise above 2.75 or fall below 0.5 bar. How do I increase the pressure on my Worcester boiler? Worcester boiler reset button flashing: if there is some fault with the system, the blue mains light will flash as well as the reset button (once per second). How to Reset a Worcester BoilerBoiler leaks usually happen due to blown pump seals. This happens when the seals degrade over time, or experience excessive stress, such as a recent increase in flow rate on the pump.

On rare occasions, your boiler pressure can seem low because the gauge is faulty and isn’t showing the correct pressure. In this case, you’ll need a boiler engineer to replace the pressure gauge. Why does my Worcester boiler keep losing pressure? Too much pressure on a boiler means there is an overfilling in the system. Hence, you need to bleed a radiator to release some of that. You are aiming to get a number between 1 and 1.5 bar. Bleeding means releasing trapped air. Boiler losing pressure but no leakIf your boiler is out of warranty and needs a diverter valve replacing, it might be wise to invest that cash in a new appliance with a long boiler warranty. The cheapest place to find a replacement Worcester Bosch boiler online currently is Heatable, where these boilers are usually offered at competitive prices and with 10-year warranties. Carbon deposits on the light— Over time, carbon build-up may obstruct the light and cause it to malfunction.

If the boiler pressure drops, it means the water is getting out which should not be happening. Worcester boiler low pressure The most likely reason you’re seeing a pressure increase is that the system has too much water in it.Put simply, re-pressurising your boiler means allowing more water to enter the system. And while other combi boilers use a filling loop to do this, some Worcester Bosch boilers use an internal filling key.

This is most likely an expansion vessel problem, if so, you will need to recharge the expansion vessel, or you’ll have to replace it if the diaphragm inside is split. Look up into the boiler to find the filling link. This is a small hole just to the right of a white square which the key will slot into Ideally, the gauge should read between 1 and 1.5. But if it reads less than 1 bar, your boiler pressure is too low and needs re-pressurising. In either situation, we’d urge you to hire a heating engineer to inspect your appliance and recommend corrective action. Is It Time for a Replacement Boiler? If the leak isn’t immediately obvious, it may be a good idea to call your boiler care company helpline or consult with a heating engineer. These professionals are trained to spot and resolve such issues promptly. Troubleshooting Leaks on a Worcester Bosch BoilerThe most common cause behind low boiler pressure (and this goes for all boilers, not only ones made by Worcester Bosch) is a leak.